Solvent move meter

Table of Contents

What is solvent flow meter?

What is a chemical solvent?

Considerations for choosing a solvent flow meter

Viscosity considerations and lack of capillary seal

Low lubricity and stress drop

Flow meters for measuring solvents

Turbine flowmeter

Oval gear circulate meter

Magnetic flowmeter

Gear flow meter

Featured merchandise

What is solvent flow meter?

Solvent flow meter is a move meter that measures the amount or mass circulate of a solvent. It is essential to precisely measure the quantity of solvent in industrial production processes. Solvents are divided into organic solvents and inorganic solvents based on their chemical composition. Solvents are generally used as uncooked supplies in numerous industries corresponding to coatings, paints and dyes.
Choosing a move meter for chemical service may be difficult. We need to know exactly what the fluid is and the working circumstances. Of specific significance are temperature and line strain. The more information you give us, the higher we can do in selecting the proper move meter on your utility.
What is a chemical solvent?

Solvents are substances that may dissolve different solids, liquids, gases and other solutes. The commonest solvent in our every day life is water. Generally solvents have low boiling factors, are risky and can’t react chemically with solutes. Solvents are usually colorless and transparent liquids with a particular odor.
Solvents play an important role in adhesives.
Organic solvents are a big group of organic compounds that are extensively used in life and manufacturing. They have a small molecular weight and are liquid at room temperature. Organic solvents include a wide range of substances corresponding to paraffins, olefins, alcohols, aldehydes, amines, esters, ethers, ketones, aromatic hydrocarbons, hydrogenated hydrocarbons, terpenes, halogenated hydrocarbons, heterocyclic compounds, nitrogen-containing compounds, sulfur-containing compounds, and so on. Compounds, etc. Most of them are poisonous to humans.
Solvents are often found in paints, adhesives, varnishes and cleaners. Commonly used natural solvents are DMF, cyclohexanone, acetonitrile, acetic acid, methyl acetate, ethyl acetate, isopropyl alcohol, vinyl acetate, cyclohexane, n-hexane, n-heptane, and so on.
Organic solvents are a class of natural compounds that can dissolve some substances insoluble in water (such as grease, wax, resin, rubber, dye, etc.). It is characterised by its liquid state at room temperature and stress. It has higher volatility. During the dissolution course of, the properties of solute and solvent stay unchanged.
There are many forms of natural solvents, which may be divided into 10 major classes according to their chemical structure.
Aromatic hydrocarbons: benzene, toluene, xylene, and so on.
Aliphatic hydrocarbons: pentane, hexane, octane, and so forth.
Alicyclic hydrocarbons: cyclohexane, cyclohexanone, toluene cyclohexanone, etc.
Halogenated hydrocarbons: chlorobenzene, dichlorobenzene, dichloromethane, etc.
Alcohols: methanol, ethanol, isopropanol, and so forth.
Ethers: ethyl ether, propylene oxide, and so forth.
Esters: methyl acetate, ethyl acetate, propyl acetate, etc.
Ketones: acetone, methyl butanone, methyl isobutyl ketone, and so forth.
Diol derivatives: ethylene glycol monomethyl ether, ethylene glycol monoethyl ether, ethylene glycol monobutyl ether, and so on.
Other: acetonitrile, pyridine, phenol, and so on.
Considerations for choosing a solvent circulate meter

Don’t just ask for physique materials and anticipate the gauge to work correctly. The physique is solely a strain vessel containing a working mechanism. The supplies within the physique have to be fastidiously specified. Always verify the listing of materials in the specs. If you expertise chemical compatibility problems, it will be in the working mechanism, not in the body.
Do not assume that a plastic-bodied gauge will be good for you merely since you are utilizing PVC strains. PVC and CPVC can deal with chemical substances that may soften a plastic-bodied gauge in seconds. Plastic physique gauges designed for water supply are made from polyacetal and polycarbonate, not PVC. they can not handle low pH fluids and are topic to solvent attack in some circumstances.
Viscosity concerns and lack of capillary seal

The application of mechanical devices requires consideration of fluid properties. Mechanical gauges with oscillating pistons, pendulums (pendulums) or related measuring parts are called volumetric gauges. However, what makes it “positive” is the capillary seal between the measuring component and the sidewall or partaking parts. If you may be dealing with low viscosity fluids, i.e. alcohol, toluene, MEK, etc., you lack the viscosity to kind a great capillary seal. This will show up as leaks around the measuring component and can usually trigger the meter to learn low.
Low lubricity and stress drop

Positive displacement circulate meters have surfaces in the measurement chamber which might be in contact with each other. In a chapter moving disc (pendulum), the middle ball rides in a formed cup, in an oscillating piston flowmeter, the middle pin is involved with the roller and the piston diaphragm rides on the hub. This implies that the non-lubricated fluid allows these elements to pull against each other, which increases the frictional load. This loading creates higher strain drops and increases wear on the meter.
Flow meters for measuring solvents

The finest methodology for such fluids is to make use of turbine flow meters. The turbine rotor is suspended by ball or sleeve bearings and has virtually no drag coefficient. This permits turbine move meters for use for low viscosity in addition to non-lubricated fluids. Another option is the oval gear flow meter (PD circulate meter), which is a positive displacement gadget using a double oval rotor. The rotors inherently provide a greater seal as a end result of their gear design captures a pocket of fluid on the capillary sealing level, thus stopping leakage around the measuring component. Electromagnetic move meters may additionally be used, and so they both allow for extremely correct and efficient solvent move measurement.
Turbine flowmeter

Turbine circulate meters are velocity circulate meters, also called impeller circulate meters. It can be used to measure the instantaneous and cumulative flow price of solvent liquids. It has the benefits of high accuracy, good repeatability, simple construction, few shifting elements, high strain resistance, extensive measuring range, small quantity, gentle weight, small stress loss, simple maintenance, etc.
Turbine flowmeter is broadly used for move measurement: petroleum, chemical trade, metallurgy, organic liquid, inorganic liquid, liquefied gasoline, natural gas, fuel and low temperature fluid. Turbine flowmeter signal could be divided into pulse sign or present sign (4-20mA).
Oval gear flow meter

Oval gear flow meter as a mechanical move meter is a standard type of volumetric move meter. It can measure the amount circulate of high viscosity and corrosive solvent fluids. It has several advantages.
High measurement accuracy.
Installation piping conditions don’t have any effect on the measurement accuracy.
Can be used for prime viscosity fluids.
Large vary.
Direct reading meter can get hold of the totalization and total immediately with out external power.
Clear and simple to operate.
Magnetic flowmeter

Magnetic circulate meter is a flowmeter that measures the circulate of conductive solvent fluids. Abbreviated as EMF, it’s also called electromagnetic flowmeter. It is a volumetric circulate meter. The electromagnetic move meter measures the speed of a conductive fluid passing through a pipe or conduit. Electromagnetic flowmeter is the best flowmeter alternative for the wastewater remedy industry.
Gear move meter

The gear flow meter is a miniature digital volumetric move meter. Can measure very small circulate charges and quantify small volumes of liquid. Resistant to excessive and low temperatures (-196°C – 200°C).
The gear flow meter is manufactured from stainless steel and is used for correct continuous or intermittent measurement of the circulate rate or instantaneous move of liquids. It is very suitable for move measurement of heavy oil, polyvinyl alcohol, grease and other excessive viscosity media. It can measure the viscosity of fluids as a lot as 10,000 Pa.s.
Generally talking, we are able to select the suitable flowmeter based on the different characteristics of chemical solvents. For example, high viscosity solvents are beneficial to make use of gear circulate meters. For example, for corrosive solvents, electromagnetic flowmeter can be utilized. If you need to cut back the price, you probably can choose turbine flowmeter.
Of course must be based on our actual measurement situations, corresponding to media temperature, pipe temperature, pressure, etc.. Select the appropriate flowmeter to attain accurate measurement.
Featured products

AYT Digital Liquid Magnetic Flow Meter

Learn More AYT Digital Liquid Magnetic Flow Meter

AFT Split Type Electromagnetic Flow Meter

Learn More AFT Split Type Electromagnetic Flow Meter

ACT Insertion Type Magnetic Flowmeter

Learn More ACT Insertion Type Magnetic Flowmeter

LWGY Liquid Turbine Flow Meter

Learn More LWGY Liquid Turbine Flow Meter

AQT Steam Vortex Flow Meter

Learn More AQT Steam Vortex Flow Meter

APT Air Vortex Flow Transmitter

Learn More APT Air Vortex Flow Transmitter

More prolonged reading on flow meters:
Flow meter vs flow transmitter

Select the proper irrigation flow meter

Electronic move meter

Hot water flow meter

Chilled water circulate meter
#keyword# is just not the simplest subject to make an effort to wrap your mind around but if you use what we have tutored you, it shouldn’t be that complicated for you to truly find it out. For the very best possible outcomes, you need to concentrate on just a single issue at any given time and never try to hope to understand all of it at the same time. Not merely is your degree of knowledge crucial, exactly what you decide to do all the time is vital also. When you will be ready to improve your amount of knowing here, #links# is complete with excellent methods and suggestions that you could use. There tend to be so many different aspects to #keyword# to learn about but there is even now a reasonable amount that you may accomplish by learning a little bit and then placing that awareness to good use.


Table of Contents

What is solvent circulate meter?

What is a chemical solvent?

Considerations for choosing a solvent flow meter

Viscosity issues and lack of capillary seal

Low lubricity and stress drop

Flow meters for measuring solvents

Turbine flowmeter

Oval gear circulate meter

Magnetic flowmeter

Gear move meter

Featured products

What is solvent flow meter?

Solvent circulate meter is a circulate meter that measures the quantity or mass flow of a solvent. It is very important to accurately measure the amount of solvent in industrial production processes. Solvents are divided into organic solvents and inorganic solvents in accordance with their chemical composition. Solvents are generally used as raw materials in varied industries corresponding to coatings, paints and dyes.
Choosing a move meter for chemical service may be tough. We have to know exactly what the fluid is and the operating situations. Of explicit significance are temperature and line strain. The extra info you give us, the better we are able to do in choosing the proper circulate meter for your utility.
What is a chemical solvent?

Solvents are substances that can dissolve different solids, liquids, gases and different solutes. The most common solvent in our daily life is water. Generally solvents have low boiling factors, are unstable and cannot react chemically with solutes. Solvents are often colorless and transparent liquids with a distinctive odor.
Solvents play a very important function in adhesives.
Organic solvents are a large group of natural compounds which are extensively utilized in life and production. They have a small molecular weight and are liquid at room temperature. Organic solvents include a wide range of substances such as paraffins, olefins, alcohols, aldehydes, amines, esters, ethers, ketones, fragrant hydrocarbons, hydrogenated hydrocarbons, terpenes, halogenated hydrocarbons, heterocyclic compounds, nitrogen-containing compounds, sulfur-containing compounds, etc. Compounds, and so forth. Most of them are poisonous to people.
Solvents are normally present in paints, adhesives, varnishes and cleaners. Commonly used natural solvents are DMF, cyclohexanone, acetonitrile, acetic acid, methyl acetate, ethyl acetate, isopropyl alcohol, vinyl acetate, cyclohexane, n-hexane, n-heptane, and so on.
Organic solvents are a class of natural compounds that may dissolve some substances insoluble in water (such as grease, wax, resin, rubber, dye, and so on.). It is characterized by its liquid state at room temperature and strain. It has higher volatility. During the dissolution process, the properties of solute and solvent stay unchanged.
There are many types of natural solvents, which could be divided into 10 main classes based on their chemical construction.
Aromatic hydrocarbons: benzene, toluene, xylene, and so on.
Aliphatic hydrocarbons: pentane, hexane, octane, and so on.
Alicyclic hydrocarbons: cyclohexane, cyclohexanone, toluene cyclohexanone, and so on.
Halogenated hydrocarbons: chlorobenzene, dichlorobenzene, dichloromethane, and so on.
Alcohols: methanol, ethanol, isopropanol, and so forth.
digital pressure gauge : ethyl ether, propylene oxide, and so forth.
Esters: methyl acetate, ethyl acetate, propyl acetate, etc.
Ketones: acetone, methyl butanone, methyl isobutyl ketone, and so forth.
Diol derivatives: ethylene glycol monomethyl ether, ethylene glycol monoethyl ether, ethylene glycol monobutyl ether, and so forth.
Other: acetonitrile, pyridine, phenol, and so on.
Considerations for selecting a solvent circulate meter

Don’t just ask for physique materials and expect the gauge to work properly. The body is simply a pressure vessel containing a working mechanism. The supplies within the body must be rigorously specified. Always check the listing of materials within the specifications. If you expertise chemical compatibility issues, it will be within the working mechanism, not in the body.
Do not assume that a plastic-bodied gauge will be excellent for you merely since you are utilizing PVC lines. PVC and CPVC can handle chemical substances that will melt a plastic-bodied gauge in seconds. Plastic body gauges designed for water supply are made of polyacetal and polycarbonate, not PVC. they can’t handle low pH fluids and are subject to solvent attack in some instances.
Viscosity considerations and lack of capillary seal

The utility of mechanical devices requires consideration of fluid properties. Mechanical gauges with oscillating pistons, pendulums (pendulums) or comparable measuring elements are referred to as volumetric gauges. However, what makes it “positive” is the capillary seal between the measuring component and the sidewall or participating parts. If you’re coping with low viscosity fluids, i.e. alcohol, toluene, MEK, etc., you lack the viscosity to form a good capillary seal. This will present up as leaks across the measuring component and can normally cause the meter to read low.
Low lubricity and pressure drop

Positive displacement move meters have surfaces in the measurement chamber which would possibly be in contact with one another. In a chapter transferring disc (pendulum), the middle ball rides in a shaped cup, in an oscillating piston flowmeter, the middle pin is in touch with the curler and the piston diaphragm rides on the hub. This signifies that the non-lubricated fluid permits these elements to tug towards each other, which increases the frictional load. This loading creates higher strain drops and will increase wear on the meter.
Flow meters for measuring solvents

The best method for such fluids is to make use of turbine flow meters. The turbine rotor is suspended by ball or sleeve bearings and has nearly no drag coefficient. This permits turbine flow meters to be used for low viscosity as properly as non-lubricated fluids. Another choice is the oval gear flow meter (PD circulate meter), which is a positive displacement gadget using a double oval rotor. The rotors inherently present a better seal because their gear design captures a pocket of fluid at the capillary sealing level, thus stopping leakage across the measuring element. Electromagnetic move meters may also be used, they usually each permit for extremely correct and efficient solvent move measurement.
Turbine flowmeter

Turbine move meters are velocity circulate meters, also recognized as impeller flow meters. It can be used to measure the instantaneous and cumulative move price of solvent liquids. It has the benefits of excessive accuracy, good repeatability, simple construction, few shifting components, high pressure resistance, wide measuring vary, small quantity, mild weight, small pressure loss, straightforward upkeep, and so on.
Turbine flowmeter is broadly used for move measurement: petroleum, chemical trade, metallurgy, natural liquid, inorganic liquid, liquefied gas, natural gasoline, gasoline and low temperature fluid. Turbine flowmeter signal may be divided into pulse signal or current signal (4-20mA).
Oval gear flow meter

Oval gear move meter as a mechanical move meter is a common sort of volumetric move meter. It can measure the amount move of high viscosity and corrosive solvent fluids. It has several benefits.
High measurement accuracy.
Installation piping circumstances have no effect on the measurement accuracy.
Can be used for top viscosity fluids.
Large range.
Direct studying meter can acquire the totalization and total directly without exterior power.
Clear and simple to function.
Magnetic flowmeter

Magnetic flow meter is a flowmeter that measures the flow of conductive solvent fluids. Abbreviated as EMF, it is also called electromagnetic flowmeter. It is a volumetric flow meter. The electromagnetic move meter measures the rate of a conductive fluid passing through a pipe or conduit. Electromagnetic flowmeter is the best flowmeter selection for the wastewater therapy business.
Gear move meter

The gear flow meter is a miniature digital volumetric circulate meter. Can measure very small flow rates and quantify small volumes of liquid. Resistant to excessive and low temperatures (-196°C – 200°C).
The gear circulate meter is made of stainless steel and is used for correct steady or intermittent measurement of the move fee or instantaneous move of liquids. It is particularly suitable for flow measurement of heavy oil, polyvinyl alcohol, grease and other excessive viscosity media. It can measure the viscosity of fluids up to 10,000 Pa.s.
Generally speaking, we are in a position to select the appropriate flowmeter based on the totally different traits of chemical solvents. For instance, high viscosity solvents are really helpful to use gear flow meters. For example, for corrosive solvents, electromagnetic flowmeter can be used. If you want to reduce the price, you can select turbine flowmeter.
Of course need to be primarily based on our actual measurement conditions, similar to media temperature, pipe temperature, strain, and so forth.. Select the suitable flowmeter to achieve correct measurement.
Featured products

AYT Digital Liquid Magnetic Flow Meter

Learn More AYT Digital Liquid Magnetic Flow Meter

AFT Split Type Electromagnetic Flow Meter

Learn More AFT Split Type Electromagnetic Flow Meter

ACT Insertion Type Magnetic Flowmeter

Learn More ACT Insertion Type Magnetic Flowmeter

LWGY Liquid Turbine Flow Meter

Learn More LWGY Liquid Turbine Flow Meter

AQT Steam Vortex Flow Meter

Learn More AQT Steam Vortex Flow Meter

APT Air Vortex Flow Transmitter

Learn More APT Air Vortex Flow Transmitter

More prolonged studying on circulate meters:
Flow meter vs move transmitter

Select the best irrigation move meter

Electronic move meter

Hot water flow meter

Chilled water circulate meter

Scroll to Top